ASE a Kalkitech Company
  • Products

      ASE2000 V2 RTU Test Set

      ASE2000 Version 2

      ASEDLMS Meter Test Set

      ASEDLMS Meter Test Set

      ASEDLMS Meter Simulator

      DER Aggregation & DAS

      Aggregator Middleware for DER Fleets

      Data Acquisition System for DER Fleets

      ASE61850 Relay Test Set

      ASE61850 Suite

      ASE61850 Test Set

      ASE61850 IED Smart

      ASE61850 SCL Manager

      Communication & Automation

      Bell-202/202T Modems

      Substation Alarm Manager (SAM)

      ASE SPTSRV Protocol Translator/ Terminal Server

      ASE SPT-PC SCADA Data Gateway

      SYNC Products

      DER Utility Interconnection

      Direct Telemetry for Utility Interconnection

      DER Aggregator for Utility Interconnection

      Edge Middleware for UL1741 SB & CSIP Compliance

  • Services

      Training Classes

      ASE2000 & DNP3 / IEC 104 Protocols

      ASE61850 Suite & IEC 61850 Protocol

      ASEDLMS & DLMS/COSEM Protocol

      vPAC In-person Training Program

      Product Engineering Services

      New Product Development

      Life Cycle Extension

      Testing & Validation

      Hardware Development

      Certification & Compliance

      Advanced Grid Automation Technology Lab

      DER Telemetry / Rule 21 Customer Owned Telemetry

      Customer Owner Telemetry

      DER Utility Interconnection

      IEEE2030.5 DER Gateway

  • Support & Downloads

      Knowledge Center

      Supported Protocols

      Product Release Notes

      SPTSRV

      ASE2000

      Terminal Server

      Videos

      Webinar

      Frequently Asked Questions

      ASE Software Downloads

      ASE2000 Test Set and Drivers

      ASE61850 Test Set

      ASEDLMS Test Set

      SPT Protocol Translator

      Serial I/O Drivers

      SAM Annunciator

      Terminal Server

      Sales & Support

      Product Registration

      Support Request

      Request a Quote

      Warranty

      Cyber Security

      Contact Us

  • Login
  • Products

      ASE2000 V2 RTU Test Set

      ASE2000 Version 2

      ASEDLMS Meter Test Set

      ASEDLMS Meter Test Set

      ASEDLMS Meter Simulator

      DER Aggregation & DAS

      Aggregator Middleware for DER Fleets

      Data Acquisition System for DER Fleets

      ASE61850 Relay Test Set

      ASE61850 Suite

      ASE61850 Test Set

      ASE61850 IED Smart

      ASE61850 SCL Manager

      Communication & Automation

      Bell-202/202T Modems

      Substation Alarm Manager (SAM)

      ASE SPTSRV Protocol Translator/ Terminal Server

      ASE SPT-PC SCADA Data Gateway

      SYNC Products

      DER Utility Interconnection

      Direct Telemetry for Utility Interconnection

      DER Aggregator for Utility Interconnection

      Edge Middleware for UL1741 SB & CSIP Compliance

      KALKI.IO Login
  • Services

      Training Classes

      ASE2000 & DNP3 / IEC 104 Protocols

      ASE61850 Suite & IEC 61850 Protocol

      ASEDLMS & DLMS/COSEM Protocol

      vPAC In-person Training Program

      Product Engineering Services

      New Product Development

      Life Cycle Extension

      Testing & Validation

      Hardware Development

      Certification & Compliance

      Advanced Grid Automation Technology Lab

      DER Telemetry / Rule 21 Customer Owned Telemetry

      Customer Owner Telemetry

      DER Utility Interconnection

      IEEE2030.5 DER Gateway

      KALKI.IO Login
  • Support & Downloads

      Knowledge Center

      Supported Protocols

      Product Release Notes

      SPTSRV

      ASE2000

      Terminal Server

      Videos

      Webinar

      Frequently Asked Questions

      ASE Software Downloads

      ASE2000 Test Set and Drivers

      ASE61850 Test Set

      ASEDLMS Test Set

      SPT Protocol Translator

      Serial I/O Drivers

      SAM Annunciator

      Terminal Server

      Sales & Support

      Product Registration

      Support Request

      Request a Quote

      Warranty

      Cyber Security

      Contact Us

      KALKI.IO Login
  • Shop
  • Login

EasyConnect

Release Date-09 June 2020

Latest release of easyConnect configuration utility.

Download Release Note
  • Home
  • ASE2000 V2 Release Notes

ASE2000 V2 Release Notes

Change Type Protocol Description / Links
Enhancements All Comma Separated Values for simulation in RTU mode.
Extended RTU mode simulation to 10 minutes in Trial License.
Added feature to capture traffic into binary text files. (Only Database capture was available earlier).
Installer includes all necessary driver modules.
Support of Network License.
Integrated License Management tool into ASE2000.
Bug Fixes All Fixed a crash issue in DNP3 Certification Procedures.
Fixed issue in drag-and-drop of exchange to header row.
Refresh line monitor view for offline messages with changes in exchange configuration.
“First Point ID” applied for TRW Protocol.
Fixed the issue in SPT DNP3 traffic display.
Fixed the issue of display of quality code as offline.
Fixed the issue of SEL FM device polling.
Fixed stability issue during SBO command in IEC104.
Fixed issue in importing a2k files.
Fixed issues in file imports.

Change Type Protocol Description / Links
Enhancements All Support of time limited Subscription license
Bug Fixes All Fixed a crash issue caused by Exchange highlighting feature

Change Type Protocol Description / Links
Enhancements All In Task mode, under Master Simulation mode, Once Button is enabled when a task is already active
Ongoing exchange is highlighted when communication is in progress; Selected exchanges are automatically sorted to the top of the list. Manual sort option is also provided to move exchanges up and down for easy viewing.
Increased the buffer size of Msgx file captures.
Bug Fixes All Fixed unexpected crashing issues
Fixed the issue of automatic changing of capture file Max
Entries value.
Fixed the issue of slow response in case of double click on Point List and launch of “Modify Point List” window.

Change Type Protocol Description / Links
Enhancements All Exchange Editing: New ASE2000 V2 Test Set will allow User to edit exchange (s) even when the communication is live or active. This gives a lot of flexibility to modify the tests even when test (s) is already running
Message Filter: New ASE2000 V2 Test Set provides an easy interface to manage filtered messages as per User requirements. Filtered messages can be viewed even when the communication is live or active.
Bug Fixes All Fixed exception error while clicking on exchange list options after running simulation in Task mode
Fixed exception error with index out of range error message transmitting all the options in Exchange list.
Fixed exception error while switching between Task mode and Exchange mode
Fixed exception error while configuring RTU with inappropriate entries
Fixed exception error while veiwing the capture file
Fixed Save option not visible error in Task mode (for Project Saving in Task mode)

Change Type Protocol Description / Links
Enhancements All Added Project Saving feature.
Added SPT file parsing import ability.
Bug Fixes All Fixed issue with “Display Enabled Exchanges Only” option where filtering is now applied on message import.
Fixed issue with brackets “” swapped around on text
file imports.
Fixed Message Query filtering issue where query string would append an unneeded argument.
Bug Fixes DNP3 In Exchange mode, “transmit” flags for “Security Statistics” and “Security Statistics Events”, object group 121, are now included in Class 0 and Class 1, 2, 3 responses respectively
DNP3 LAN/WAN properties tab SSL Certificate dropdowns sometimes causing a crash when there are no SSL certificates on the machine.
Fixed Message Query filtering issue where query string would
append an unneeded argument.
Cosmetic All IAdded warning for “switched” when the carrier setting is switched in Master Simulation mode.

Change Type Protocol Description / Links
Enhancements All Added ability to export raw data bytes to a text file
Added option to allow user selection of SSL certificate.
Added import of Wireshark files for Linux/cooked files.
Change event file size from bytes to MB.
Added notification when support subscription is about to expire.
Enhancements Conitel Added Conitel Byte mode protocol for monitoring
Bug Fixes Scripting Fixed “AnyOf” and “SkiptoTest” functions
Fixed the issue of automatic changing of capture file Max Entries value.
Bug Fixes PG&E Corrected parsing of Write-2 message when the length is greater than 1

Change Type Protocol Description / Links
Enhancements All Add ability to display security data in brackets in raw monitoring data view
For network protocols, do not start timeline movement until connection is complete.
Line Monitor view keyboard control: PgUp, PgDn, Home, and End.
Added text search to line monitor view.
Enhancements DNP3 Allow entry of specific date/time for LAN/WAN time sync
Bug Fixes IEC 60870 Corrected control loopback for double points in IEC 60870- 5-101 and -104. Prior code was writing wrong value to associated input point in RTU simulation mode. Impacted double points only
Bug Fixes IEC 60870- 103 Allow time entries for year 2038 and later
Bug Fixes SC 1801 Correct reception in RTU simulation mode
Bug Fixes All Fixed issues with control dialog added in release 2.18
Fixed text import issues of sometimes missing final byte
Bug Fixes DNP3 Secure authentication, disable aggressive mode in first message after a key exchange

Change Type Protocol Description / Links
Enhancements All Point Values View: Made the time a point change is highlighted a user selected parameter. Previously it was always 5 seconds
Allow import of messages created by another program as text files
Added exchange modem analog and digital control dialogs similar to ASE2000 version 1.
Bug Fixes All Improved color highlighting for raw data when selecting a corresponding “interpreted date” entry. Prior coloring was reported as too faint
Bug Fixes DNP3 Slight enhancement to bit value text shown in messages view
Fixed task mode issue sending file requests to device that does not support files.

Change Type Protocol Description / Links
Enhancements Added ability to load ASE2000 Version 1 MON files
Ongoing exchange is highlighted when communication is in progress; Selected exchanges are automatically sorted to the top of the list. Manual sort option is also provided to move exchanges up and down for easy viewing.
Enhancements Modbus/TCP Added ability to import Wireshark capture files
Enhancements DNP3 Added ability to import Wireshark capture files for DNP3
LAN/WAN
Added Script editor and execution. Please see documentation. Special license required
Added ability to specify default variation in Task Mode responses
Changed DNP3 test procedures to align with Version
2.7 changes issued by the DNP3 Users Group on 2-March-2016
Enhancements IEC 60870-5 Added Script editor and execution for 101 and 104. Please see documentation. Special license required
Added ability to import Wireshark capture files
Added ability to enter originator address
Bug Fixes All Fixed scrolling in Line Monitor view. Messages could be displayed in wrong order in rare case where a message length was exactly one character longer than a line
Fixed unexpected crashing issues
ixed the issue of automatic changing of capture file Max
Entries value.
Bug Fixes SES-92 Fixed display of setpoint execute command
Bug Fixes CDC Type 2 Corrected task mode error that included pulse data in a scan 1 response
Bug Fixes DNP Fixed DNP3 cert step 8.5.5.2.2 tests for multiple events returned to a Class 1/2/3/0 request
Fixed DNP3 Certification test 8.11.2.6.8 that could lock up at step 2 when events were reported unsolicited.

Change Type Protocol Description / Links
Enhancements All REMOTE MONITORING. Added integration to remote monitoring hardware (ASE SPT or Terminal Server) that collects (in real time) communication data from remotely located serial or network devices. Communication can be monitored by remote ASE2000 with network connectively to ASE listening device. Completely non-invasive. No control action is possible, only remote listening.
Added ability to start ASE2000 from command line, in task or exchange mode, with delay before starting active communication.
Allowed Task Mode monitoring for serial protocols when there is only one COM port available. In prior releases, this was supported in Exchange Mode only.
Enhancements DNP3 Added ability to generate Binary Output Status point events in task mode
Task mode, DNP3 Lan/WAN, RTU Sim, computes
reasonable value for response to delay measurement.
Change conformance test 8.7.2.2 to no longer check accuracy of time synchronization operation in accordance with change in test procedures by DNP Users Group.
Enhancements IEC 60870-5 Added support for large data bases exceeding 1,500 points
Enhancements Modbus Added Script editor and execution for 101 and 104. Please see documentation. Special license required
Enhancements Telegyr 8979 Added support for control output feedback in RTU
Simulation/Task Mode
Bug Fixes All Fixed occasional crash with large capture files
Bug Fixes DNP Corrected DNP conformance test cases:
• 6.1.2, step 28. Allow CON bit set with data link confirm

• 6.6.2.5, step 9, allow response of “link Services Not Implemented”

• 6.6.3.1., step 2, allow data link confirm in LAN/WAN

testing

• 8.6.5.3, allowed selection of ON or OFF for control action

• 8.9.2.2, step 14

• 8.19.2.1, corrected allowed analog variation
Corrected response processing for multi-fragment messages
Bug Fixes Harris Corrected Task mode operation
Bug Fixes IEC 60870-5- 104 Disconnects if t1 timer expires
Allow entry of individual point IDs when “SQ” field is cleared
Corrected EOI message transmission in RTU Simulation mode
Bug Fixes Indactic 33 Corrected encoding of setpoints
Bug Fixes Modbus Byte ordering in Force Multiple Coil request corrected
Bug Fixes Native Async Allow use of non-ASE Com ports
Bug Fixes SES-92 Added task mode support
Bug Fixes Telegyr 6500 Corrected parsing of timestamp

Change Type Protocol Description / Links
Bug Fixes Fixed crash for some data base actions invoked with an empty RTU/device data base.
Fixed crash resulting from lack of permissions on user’s account.
Corrected crash in task mode, CDC2 protocol, RTU simulation.
Conitel Corrected RTU simulation issue entered MCD values from point values view
DNP3 Fixed “display enabled exchange only “option”
Corrected simulation of more than one outstation device in Task mode
Incrementing floating point analog values in RTU simulation maintains fractional value. before, values were truncated to whole numbers
IEC 60870-5 Fixed “Test Command” responses when operating as a control station
Fixed setpoint SBO sequence
Do not disable timer for supervisory messages when SBO sequence is active
Bad cause of transmission in response will terminate a SBO sequence
P/N bit set in response will now terminate a SBO sequence
Telegyr 8979 Corrected handling of multiple block responses
TRW 9550 Corrected BCH polynomial. Users should delete any pre- existing TRW9550.OPTX file before launching the new ASE2000.
Valmet 5 Corrected response to Configuration request command
Corrected response processing for multi-fragment messages
Enhancements All Changed wording for analog alarms to including engineering units
Corrected port open error on restart for Task and RTU simulation modes
Added build information to MSGX files to improve customer support
Enhancements Modbus Added support for 64-bit floating point
Enhancements IEC 60870-5 Disallow two control sequence from being simultaneously active
Added ability to specify Originator Address
Enhancements DNP3 Added option to include/exclude binary and analog output status points from a class scan response

Change Type Protocol Description / Links
Bug Fixes All Corrected crash when opening Properties dialog with no Task RTU selected (2.13 issue only).
Corrected crash issue in some cases when maximum size of a capture file was exceeded.
Corrected problem preventing insertion of an exchange into an empty exchange list.
Communication would not start when the events log file could not be created. Communication is now allowed to continue in cases where no event logs are enabled.
Corrected parsing response with multiple octet string objects.
Improvements to Secure Authentication V5 were made for 2.13.
Fixed issues with “unsolicited” portion of conformance test procedures.
Bug Fixes DNP3 RTU Simulation, Task mode, would sometimes stop being responsive after several minutes. This problem was introduced in release 2.12 and corrected in 2.13.
Corrected simulation of more than one outstation device in Task mode
Incrementing floating point analog values in RTU simulation maintains fractional value. before, values were truncated to whole numbers
Bug Fixes CDC 1 Task mode, response to setpoint output command might contain wrong setpoint value.
Bug Fixes Harris 5000 Corrected RTU Simulation in Task Mode
Bug Fixes IEC 60870-5-101 Corrected rare master simulation startup condition that would fail to send class 1/class 2 messages after a GI completed.
Bug Fixes Getac 7020 LP Fixed naming error that restricted access to exchange list
Bug Fixes TRW 9550 Fixed calculation of BCH Security Code
Bug Fixes DNP3 Added option to include/exclude binary and analog output status points from a class scan response
Enhancements All Provide more detailed explanations when ASE2000 license cannot be validated
Increased Capture database size to permit larger amounts
of communication data to be stored
Added feature to select range of captured messages to be viewed for large capture sets
Added feature for exporting capture data directly to a .MSGX file
Enhancements Network Protocols Added “LAN Properties” button to allow selection of a specific adapter when monitoring network protocols
Enhancements IEC 60870- 5-101 & IEC 60870-5-104 Added Directory command to Task Mode File Operations
Enhancements DNP3 Enhanced “Mouse Over” wording for selected conformance testing failure conditions to provide more information
Master Simulation, Task mode. Added “Process IIN” option to process Need Time, Restart, Class 1, Class 2, and Class 3 IINs. If checked, appropriate action will be taken after a response with any of these five IIN sets.

Change Type Protocol Description / Links
Bug Fixes All Corrected occasional crash when choosing “Reset to Defaults” from View pull-down list.
Corrected crash with CSV data base import function.
Fixed slow memory leak for dongle users.
Bug Fixes DNP Corrected obscure memory leak occurring when operating in RTU Simulation unsolicited data reporting when the master has stopped. Continual transmission of events with no acknowledgment caused a problem.
RTU Simulation. Corrected error response on request for analog input data (object 30)
Conformance test step, 2.11, section 6.6.2.2, step 5 allows the DUT to either not respond or to send a “Link Server Not Implemented” response. Corrected errant failure when device returns the “Not Implemented” response
Certification procedures would not run correctly if started with the “play” option, but would work OK when started with “Send Once”. Version 2.12 supports the “Play” option to run the tests repetitively
Fixed memory leak in DNP3 Exchange mode
Corrected certification procedure checks for Outstations that use the data link “Not Implemented” function code
Fixed RTU simulation problem reporting too many holding registers.
Bug Fixes IEC 60870-5-101 and 104 Allow negative setpoint values
Corrected RTU simulation reporting issue with multiple non-contiguous blocks of the same ASDT type
Bug Fixes IEC 60870-5-103 Fixed transmission of GDD values for Generic Data.
Enhancements Conitel, DNP, IEC 60870-5-101 and 104, Modbus RTU Simulation, Task Mode. Added ability to define cross mapping to derive digital or analog input value from digital or analog output control. In Description field in Point’s List, enter source address in square brackets. For example, [6] in the description field for an Analog Input point will set that point’s value after a control to analog output point 6. For Conitel, enter [group.point]. Feature must also be enabled from Properties menu.
Enhancements IEC 60870-5-101 and 104 Added qualifier column to exchange properties menu
Enhancements Telegyr 8065 Added support for new protocol
Enhancements DNP3 Enhanced operation of secure authentication version 5

Change Type Protocol Description / Links
Bug Fixes All Corrected occasional abort when activating Event Log view.
Fixed several display aborts and corrected tooltip information.
Bug Fixes IEC 870-5-101 and -104 In RTU Simulation mode, corrected processing or Counter Interrogation requests.
Fixed multiple file transfer problems
Bug Fixes IEC 870-5-103 Corrected error where data link size could be set to 2 octets.
Corrected problem where manual entry of generic Command data was not saved.
Process ACD bit if sent in response to Reset Link.
Bug Fixes DNP3 Fixed crash dealing with secure authentication
Fixed timing issues with some certification procedures
Following DNP3 certification errors were introduced in
release 2.9 and have now been corrected:

• 6.3.2, step 4 sent wrong message

• 8.6.5.2 step 5 now sends message to broadcast address
Corrected interpretation of status code in Binary Output Command Events
Correct task mode “Remote File Directory” processing for DNP3 serial
Fixed abort detected by “Fuzzy” testing group
Bug Fixes Conitel Task Mode, RTU Sim, corrected responses to control
select commands.
Bug Fixes DNP3 Added clarity to certification test failure reports
Added option to disable UDP listen in master simulation mode, allowing two DNP3 LAN/WAN tests sets running in the same PC to communicate to each other
Enhanced automated processing of certification tests for digital and analog output status reads
Enhancements All Added block entry for a set of point raw or increment values from the Point Values view
Added ability to import RTU/point data from a CSV file
Added triggers on queries, which can include DNP3 Internal Indication and DNP3 security messages
Ability to set default port numbers when launching
Enhancements Network Added support for IPv6 (IPv6 addresses are represented as eight groups of four hexadecimal digits)

Change Type Protocol Description / Links
Bug Fixes DNP3 Corrected Data Link confirm error introduced in 2.9

Change Type Protocol Description / Links
Bug Fixes All Properties/Event/Display processing corrected. In previously releases, it would not create an event entry in the Line Monitoring view.
Added support for certain third-party USB-to-Serial adapters. Previously releases worked only on a subset of these adapters.
Corrected occasional crash when configuring RTUs from the Points List view
Bug Fixes Conitel Improved task mode scanning for devices with multiple scan groups with multiple points types in each.
Fixed RTU Sim task mode responses to controls to groups 1 and higher
Bug Fixes CDC 2 Fixed data entry of analog points in Task Mode RTU Simulation.
Bug Fixes DNP3 Fixed data entry of analog points in Task Mode RTU
Simulation.
Fixed RTU Simulation responses of Digital Output Status.
Added support for non-ASE manufactured serial ports in Task Mode. Previously release supported these ports in Exchange Mode only.
Fixed Exchange Mode responses to analog outputs to more than one point.
Added support for non-ASE manufactured serial ports in Task Mode. Previously release supported these ports in Exchange Mode only.
Fixed Exchange Mode responses to analog outputs to more than one point.
Corrected problem where “Object Unknown” IIN could be incorrectly sent when generating unsolicited binary changes.
Fixed support for long floating point values.
Correct intermittent failure monitoring LAN/WAN in task mode.
Corrected memory leak.
Bug Fixes Conitel Task Mode, RTU Sim, corrected responses to control select commands.
Bug Fixes Modbus Corrected configuration of “Read Multiple Register” requests in Modbus/TCP
Bug Fixes SES-92 TCP Corrected TCP parameters
Bug Fixes Telegyr 8979 Fixed problem handling a Time Bias request in RTU Simulation task mode
Bug Fixes Wisp Corrected misidentification of RTU IDs other the ID 0
Enhancements DNP3, IEC 101, IEC 104, Modbus In Task Mode, added ability for states in digital output commands and values in analog output commands to be echoed back in, respectively, digital and analog input
points. Select “Copy Output to Input” from the Properties/

Protocol tab
Enhancements Tejas V 2- byte Added option to select between CRC-16 and LRC
security
Enhancements IEC 101, IEC 104 Added ability to enter structured address IDs. Prior versions displayed structured addresses but did not support entry
Enhancements VanComm Added ability to enter signed values for analog output commands

Change Type Protocol Description / Links
Bug Fixes DNP3 Allowed “on times” greater than 255 milliseconds in Task Mode.
Corrected Clear Restart task to use qualifier code 0 instead of 1.
Bug Fixes All Corrected a customer reported crash.
Bug Fixes CDC 1 Corrected problem with SCAN 1 requests issued in task mode.
Bug Fixes IEC 60870 -5-101 Corrected error where GI task would stop issuing class 1 and class 2 requests after a response timeout.
Bug Fixes TRW System 9 Corrected problem where this protocol could not be selected.
Enhancements DNP3 Added more control over qualifier selection in Task Mode
Added ability to change “Internal Indication” settings during active communication without stopping. Changes are made via the Tools pull-down list and the Runtime Changesentry. This feature works in RTU Simulation Exchange Mode only. (see also prior entry for “All” protocols)
Added Warm Start and Cold Start exchanges
Added support for Secure Authentication version 5
Enhancements aLL Adjust “RTU ID” column width in Point Values view to show entire value for IDs over 1000
Improved processing time for RTU Simulation with large point counts
Added ability to change “Forced Error” settings during active communication without stopping. Changes are made via theTools pull-down list and the Runtime Changesentry. This feature works in Exchange Mode only
Added error message when log file size is exceeded
Upgraded installer to work on Windows 8
DNP3 Certification Procedures • Corrected determination of BAD FIR in certain unsolicited tests. In a prior release, the check was coded incorrectly.
• A pause was inserted in Unsolicited Class scan sections 8.11.2.2, 8.11.2.3, and 8.11.2.4 after step 16 for the time period specified by the procedures

• Removed some crashes in the unsolicited test section. These crashes could have occurred if the DUT sent messages to the ASE2000 too early

• Corrected occasional failure to reconnect in section 8.11, unsolicited tests for LAN/WAN protocol

• Corrects oversight in conformance test procedures checking multiple outputs for devices that only allow one control output per message. Steps 13 and 14 of sections 8.2.4.2 and 8.4.4.2 should be skipped and now are when the maximum controls per message is set to ‘1’

• Corrected auto verification of test 8.9.2.2 when

response contains more than two fragments

• Added prompt to end of test 6.1.2 to disable Data Link

confirms

• Added clarification to selected prompts requesting control point verification. Also added prompts to sections 8.2.1.2.13, Step 6, 8.2.1.2.15, Steps 6 and 9, 8.2.2.2.2, Step 3, and 8.2.2.2.3, step 5

• Corrected error when tests 6.6.2 and 6.6.3 were run automatically together. Worked OK when they were run separately.

Change Type Protocol Description / Links
Bug Fixes DNP3 Corrected abort in certification procedures.
Corrected setting application confirm bit in multi-fragment responses without events.
Bug Fixes All Increased stability.
Corrected problem when Device list is empty.
Fixed problem with Messages view when “Auto-Expand” level was set to a large number.
Bug Fixes Conitel Improved scan task with multiple groups defined.
Fixed point ordering when most significant bit is the first digital input point.
Enhancements IEC 60870 Added interpretation for file transfer FRQ octet.

Change Type Protocol Description / Links
Bug Fixes General Improved stability on capture file creation.
Bug Fixes DNP3 Exchange mode, use Destination and Source entered for an individual exchange instead of defaults.
Fixed timing problems with certification tests/unsolicited reporting.
Saves Dest and Source address in MONX files.
Bug Fixes IEC 60870- 5-101/104 Task mode, corrected problem where file transfers started at section 0. It now starts at section 1.
Corrected problem collecting data in large capture files.
Corrected abort sending Bitstring Command in Task Mode.
Corrected problem in RTUs configured with more than 242 points.
Bug Fixes Modbus Corrected display of point indices for Input Status points.
Corrected display of negative values in 32-bit analogs.
Corrected display of negative values in 32-bit analogs.
Enhancements General Cannot accidentally exit Points List editing by pressing ESC.
Cannot accidentally delete a RTU by simply pressing the Delete key.
Enhancements DNP3 Certification Test Procedures.
• In Time Sync test, added log for time that control output was issued
• Associates each message with a test step. Prior version

only identified the start of each test section

• Added ability to set OnTime for relay output tests

• Added ability to specify relay type (trip/close, latch on/

off, momentary)

• Added ability to define value to be sent in analog output

tests

• Corrected test 8.9.2 to allow for a single fragment response
Task mode, RTU Simulation. Added ability to simulate more than one RTU.
Enhancements IEC 870-5 Task mode limits point change generation during General Interrogation.
Task mode, RTU Simulation. Added ability to simulate more than one RTU.
Enhancements SES-92 Added task Mode support.

Change Type Protocol Description / Links
Enhancements IEC 60870-5- 101 and 104 Supports General Interrogation to the Broadcast Common address (FFFFx) as well as to individual addresses.
Support added to Task Mode for both Master and RTU Simulation.
Enhancements Telegyr 8979 Added interpretation of SOE LOG message.
Enhancements All Added ability to automatically alternate between Trip and Close when issuing multiple commands in Task Mode.
Bug Fixes DNP3 Certification Common Time Of Occurrence should be returned with Qualifier 7 (Count). Prior release was incorrectly coded for qualifier 0 (start/stop).
Bug Fixes IEC 60870-5- 101 and 104 Corrected RTU simulation issue that would not report changes for Double points.
Bug Fixes All Default location of Event Log file was changed to My Documents.

Change Type Protocol Description / Links
Enhancements All Initial Release
ASE a Kalkitech Company
  • www.ase-systems.com
  • www.kalkitech.com

Email

  • support@ase-systems.com
  • sales@ase-systems.com

Our Company

  • About Us
  • Blog
  • Careers
  • Contact Us
  • News & Events

Address

    Applied Systems Engineering Inc.,
    2105 S Bascom Avenue, Suite 150
    Campbell, California
    95008-6900

Legal & Privacy

  • Terms of Use
  • Site Map
  • Privacy Policy
  • Cookie Policy

Contact Us

  • +1-408-364 -0500
  • +91-80-67021900

Follow Us

Subscribe Newsletter

Copyright © 2025 Applied Systems Engineering Inc., a Kalkitech Company |
All Rights Reserved

Designed by Webandcrafts


Subscribe for our newsletter

* indicates required

Please select all the ways you would like to hear from Kalkitech / ASE:

You can unsubscribe at any time by clicking the link in the footer of our emails. For information about our privacy practices, please visit our website.

We use Mailchimp as our marketing platform. By clicking below to subscribe, you acknowledge that your information will be transferred to Mailchimp for processing. Learn more about Mailchimp's privacy practices here.


img

Request for Demo

[salesforce form="8"]
Existing Users Log In
   
Forgot password? Click here to reset
New User? Click here to register
Back To Login
New User Registration
*Required field
By continuing to browse the site you are agreeing to our Cookie Policy and Privacy Policy